HomeSolutionsTechnologyProjectsAboutNewsSearchGet a heat assessment

Proven Thermal Energy Storage. Engineered for Impact.

More than a decade of thermal energy storage development, proven across industrial and utility deployments.

bGen™ thermal energy storage

Charge. Store. Dispatch.

Developed over more than 10 years, the bGen™ system is a solid-state thermal energy storage solution engineered for high efficiency, durability and industrial-scale operation.

At the core of bGen™ is a modular thermal-storage unit filled with crushed rock—an abundant, stable and non-toxic storage medium capable of repeated thermal cycling at temperatures up to 650°C (1,200°F).

Electricity from renewable generation or the grid is converted into heat by embedded electric heaters and retained inside a highly insulated vessel. When industrial demand calls for energy, bGen™ dispatches the stored heat as high-temperature steam, hot air or thermal oil. This allows energy purchasing to be separated from heat consumption while maintaining the temperature, pressure and availability required by the industrial process.

The modular architecture scales from individual industrial installations to large energy infrastructure. Minimal moving parts support low maintenance and a long operating life, while fast response and integrated controls enable load shifting, demand management and coordinated operation with renewable generation, batteries and the grid.

The technology has been deployed across industrial and utility settings, including Enel in Italy, the Tempo brewery, SUNY Purchase College with the New York Power Authority, and FORTLEV in Brazil.

bGen™ thermal storage module during system manufacturing
How it works

How we build a bGen™ system

A bGen™ installation is configured around the customer’s heat demand, operating profile and available electricity supply. Modular storage units, electric charging, heat exchangers, process integration and digital controls are engineered as one operating system.

bGen™ thermal storage technology
Charge. Store. Dispatch.

Powered by bGen™

Transforming electricity into dispatchable industrial heat—the foundation that lets Brenmiller Europe optimize electricity and heat together. Energy can be charged when renewable production is available or electricity prices are favorable, stored safely as heat and dispatched when the industrial process needs it.

Grid-integrated bGen™ thermal energy storage installation
Integrated operation

Generation flexibility. Operational flexibility.

Consume, generate, store and shift energy according to cost, availability, reliability and carbon intensity. Bi-directional optimization supports predictable energy pricing for industry while creating valuable flexibility for the grid.

Industrial energy infrastructure
End-to-end delivery

Complete energy freedom

One partner for clean electricity and industrial heat—built, owned, operated and optimized end to end. Brenmiller Europe combines bGen™ with generation, flexible assets and digital control to deliver resilient energy infrastructure at the best available market cost.

In detail

Technical specifications

Modular configurations are engineered around the required storage duration, charging profile and industrial heat demand.

Storage capacity
10 MWh – 500 MWh
Charging load
2 MW – 100 MW
Heat output
1 MWth – 80 MWth
Temperature range
100°C – 500°C
Efficiency
Up to 97%
Design lifetime
30 years
Energy density
300 kWh/m³
Manufacturing

Industrial manufacturing capacity

Produced at a dedicated thermal energy storage manufacturing facility with capacity to support deployment of up to 4 GWh of thermal storage annually.

Industrial manufacturing capacity
Industrial energy infrastructure

Put bGen™ to work in your energy system.

Frequently asked questions

Your questions.
Answered.

How bGen™ charges, stores energy and delivers heat to an industrial process.

Discuss your heat requirements

What does bGen™ use to store thermal energy?

bGen™ uses crushed rock inside an insulated, modular thermal-storage unit. The rock retains heat until energy is needed by the industrial process.

How is the bGen™ system charged?

Embedded electric heaters convert electricity from renewable generation or the grid into heat. The insulated storage vessel retains that heat for later use.

What forms of heat can bGen™ supply?

bGen™ can support industrial steam, hot air, hot water and thermal oil applications. The installation is engineered around the customer’s process requirements and heat-delivery conditions.

Why separate electricity charging from heat delivery?

Thermal storage allows energy to be charged when renewable electricity is available or electricity prices are favorable, then dispatched when the industrial process needs heat. This separates the timing of electricity purchasing from heat consumption.

How is a bGen™ installation configured for a site?

The configuration starts with the customer’s heat demand, operating profile and available electricity supply. Modular storage units, electric charging, heat exchangers, process integration and digital controls are engineered together as one operating system.